Transformers>>LET-303DC 230

LET-303DC 230
Highly sensitive manually resettable electronic short circuit protection to meet standards for open conducted systems. Detection time below 1 msec. Will shut off short circuit caused by 34AWG wire at min load at 12m. Self dimming if ambient temperature next to transistors moves above 85°C.
  • Dimensions 9 1/4" x 3 5/8" x 1 3/4"
  • Weight 750 grams
  • Tc 80°C
  • Ta 45°C
  • Maximum load 300w
  • Minimum load without dimmer 50w
  • Minimum load with dimmer 75w
  • Input 230-240V 50/60Hz
  • Output at max load 11.5V DC
  • Input current at max. load 1.25-1.3A
  • Output current at max. load 25A
  • Power factor 0.999
  • Max. harmonic distortion at full load 4%
  • Dimmable with leading and trailing edge dimmers
  • EMC up to 12m as per EN55015
  • Safety as per EN 61046